很多朋友在(zai)拿(na)到粉(fen)碎机操作(zuo)时会有疑问,怎(zen)么样才能正确操作(zuo)呢?那么今(jin)天小编教(jiao)大家用六步来操作(zuo)超声波细胞粉(fen)碎机。请看下文:

 1.用电源线连接(jie)发(fa)生器背面的(de)(de)电源输入(ru)(ru)接(jie)口(kou)(220VAC 50Hz),把(ba)(ba)(ba)换(huan)能(neng)器组件的(de)(de)信(xin)(xin)号输入(ru)(ru)接(jie)口(kou)与(yu)发(fa)生器的(de)(de)信(xin)(xin)号输出接(jie)口(kou)连接(jie),把(ba)(ba)(ba)温度传(chuan)感器连接(jie)到温度计接(jie)口(kou),把(ba)(ba)(ba)换(huan)能(neng)器组件放(fang)(fang)到隔音(yin)箱顶部中间的(de)(de)孔内,把(ba)(ba)(ba)被破(po)碎的(de)(de)物质放(fang)(fang)置(zhi)在隔音(yin)箱的(de)(de)升降台(tai)(tai)上,把(ba)(ba)(ba)升降台(tai)(tai)上升至(zhi)变幅(fu)杆浸入(ru)(ru)溶液10mm-15mm。即完成了本(ben)仪器的(de)(de)安装(zhuang)。  

 2.检查仪器(qi)后(hou)面板上变幅杆(gan)选(xuan)择开(kai)关是否(fou)选(xuan)择在与(yu)变幅杆(gan)相(xiang)应(ying)(ying)(ying)的位置。一般新仪器(qi)或新配的变幅杆(gan)应(ying)(ying)(ying)与(yu)选(xuan)择开(kai)关对应(ying)(ying)(ying)。  

 3.打开电源开关,指示(shi)灯(deng)亮(liang)。  

 4.数(shu)(shu)(shu)据(ju)设定(ding)或(huo)查询: 用(yong)户(hu)在使用(yong)时(shi)(shi),可(ke)根(gen)据(ju)前(qian)次(ci)设定(ding)的(de)数(shu)(shu)(shu)据(ju)直接启动(掉电自(zi)动保存设置数(shu)(shu)(shu)据(ju)),也可(ke)重新(xin)设定(ding):间(jian)隙时(shi)(shi)间(jian)、超声时(shi)(shi)间(jian)和保护温(wen)度(du)。  

 5.超声波细(xi)胞粉碎机(ji)设(she)定方法如下:按设(she)定键(jian),显(xian)(xian)(xian)示(shi)窗(chuang)显(xian)(xian)(xian)示(shi),进入(ru)间(jian)隔时间(jian)设(she)定状(zhuang)态,此时显(xian)(xian)(xian)示(shi)窗(chuang)所显(xian)(xian)(xian)示(shi)的是原始数据(ju),如需重新输(shu)入(ru)数据(ju)则按置(zhi)数键(jian),置(zhi)数完后再按功(gong)能键(jian)进入(ru)下一个功(gong)能设(she)定。  

 6.超(chao)声(sheng)波细胞(bao)粉碎(sui)机进(jin)(jin)入(ru)下一项功(gong)(gong)(gong)(gong)能设(she)(she)(she)定(ding):此时(shi)(shi)(shi)(shi)(shi)显(xian)示(shi)(shi)(shi)窗(chuang)(chuang)显(xian)示(shi)(shi)(shi),表示(shi)(shi)(shi)进(jin)(jin)入(ru)超(chao)声(sheng)时(shi)(shi)(shi)(shi)(shi)间(jian)设(she)(she)(she)定(ding)状态,按(an)(an)置(zhi)(zhi)(zhi)(zhi)数(shu)(shu)键(jian),设(she)(she)(she)置(zhi)(zhi)(zhi)(zhi)超(chao)声(sheng)时(shi)(shi)(shi)(shi)(shi)间(jian),完(wan)(wan)成(cheng)(cheng)后再按(an)(an)功(gong)(gong)(gong)(gong)能键(jian),此时(shi)(shi)(shi)(shi)(shi)显(xian)示(shi)(shi)(shi)窗(chuang)(chuang)显(xian)示(shi)(shi)(shi),进(jin)(jin)入(ru)全(quan)(quan)程(cheng)时(shi)(shi)(shi)(shi)(shi)间(jian)设(she)(she)(she)定(ding),按(an)(an)置(zhi)(zhi)(zhi)(zhi)数(shu)(shu)键(jian)设(she)(she)(she)置(zhi)(zhi)(zhi)(zhi)全(quan)(quan)程(cheng)时(shi)(shi)(shi)(shi)(shi)间(jian)(此时(shi)(shi)(shi)(shi)(shi)时(shi)(shi)(shi)(shi)(shi)间(jian)单位为(wei)分),完(wan)(wan)成(cheng)(cheng)后再按(an)(an)功(gong)(gong)(gong)(gong)能键(jian),显(xian)示(shi)(shi)(shi)窗(chuang)(chuang)显(xian)示(shi)(shi)(shi),表示(shi)(shi)(shi)进(jin)(jin)入(ru)保护温度(du)设(she)(she)(she)定(ding),按(an)(an)置(zhi)(zhi)(zhi)(zhi)数(shu)(shu)键(jian)设(she)(she)(she)置(zhi)(zhi)(zhi)(zhi)保护温度(du),所有功(gong)(gong)(gong)(gong)能设(she)(she)(she)置(zhi)(zhi)(zhi)(zhi)完(wan)(wan)后在确认无误时(shi)(shi)(shi)(shi)(shi)按(an)(an)设(she)(she)(she)定(ding)键(jian)再按(an)(an)启动(dong)(dong)键(jian)即开(kai)始按(an)(an)你所设(she)(she)(she)置(zhi)(zhi)(zhi)(zhi)的各项功(gong)(gong)(gong)(gong)能数(shu)(shu)据开(kai)始工作,显(xian)示(shi)(shi)(shi)窗(chuang)(chuang)开(kai)始倒(dao)计(ji)时(shi)(shi)(shi)(shi)(shi),超(chao)声(sheng)指示(shi)(shi)(shi)灯(开(kai)),间(jian)隔(ge)指示(shi)(shi)(shi)灯(停(ting))轮换亮,待(dai)全(quan)(quan)程(cheng)工作时(shi)(shi)(shi)(shi)(shi)问过后,显(xian)示(shi)(shi)(shi)窗(chuang)(chuang)显(xian)示(shi)(shi)(shi)全(quan)(quan)程(cheng)时(shi)(shi)(shi)(shi)(shi)间(jian),并闪(shan)烁跳动(dong)(dong),自动(dong)(dong)报警并停(ting)止工作。

如(ru)需(xu)重复(fu)上述(shu)实验(yan),先(xian)按(an)(an)(an)数据(ju)恢复(fu)键再(zai)按(an)(an)(an)启动(dong)键即开始工(gong)(gong)作(zuo)。如(ru)工(gong)(gong)作(zuo)中需(xu)暂停(ting)(ting),请再(zai)次按(an)(an)(an)开/停(ting)(ting)键,以此类推(tui)。 在(zai)设(she)(she)定(ding)(ding)期间,按(an)(an)(an)设(she)(she)定(ding)(ding)键则退出设(she)(she)定(ding)(ding)状态,返回工(gong)(gong)作(zuo)状态并自动(dong)保存已设(she)(she)定(ding)(ding)的(de)数据(ju)。 当由于(yu)外部(bu)信(xin)号出现故(gu)障(zhang)或出现保护(hu)的(de)情况时,则保护(hu)指示(shi)灯亮(liang),仪器停(ting)(ting)止(zhi)工(gong)(gong)作(zuo),此时提示(shi)工(gong)(gong)作(zuo)人员解除(chu)故(gu)障(zhang),待(dai)解除(chu)故(gu)障(zhang)后,按(an)(an)(an)保护(hu)复(fu)位键恢复(fu)正(zheng)常(chang)工(gong)(gong)作(zuo)。  

 

以(yi)上(shang)是小编给大(da)(da)家(jia)总结的方法,希望能帮助(zhu)到大(da)(da)家(jia),关于超(chao)声波细胞粉碎机的信(xin)息,欢迎大(da)(da)家(jia)访问(wen)上(shang)海(hai)净信(xin)网站进行了(le)解(jie)咨询!

相关推荐

相关搜索:

  • 一个直播:超声波细胞粉碎机使用方法及工作原理讲解
  • 一个直播:操作超声波细胞粉碎机的使用要点
  • 一个直播:如何挑选使用寿命长的超声波细胞粉碎机?
  • 一个直播:影响超声波细胞粉碎机的价格因素有哪些
  • 一个直播:介绍超声波细胞粉碎机的使用优势
  • 一个直播:上海净信给您介绍超声波细胞粉碎机的性能
  • 一个直播:超声波细胞粉碎机优点有哪些?
  • 一个直播:超声波细胞粉碎机安全使用注意事项详解
  • 一个直播:超声波细胞粉碎机参数怎么设置
  • 一个直播:论超声波细胞粉碎机在使用过程中的要求
  • 上一篇:一个直播:了解超声波粉碎机购买事项
    下一篇:冷冻干燥机的好处

    网站一个直播 | 产品中心 | 一个直播 | 关于我们 | 实验案例 | 联系我们 | 论文下载 | 网站地图
    电话:15157021077 传真:021-57790918  地址:上海市闵行区七莘路1839号财富108广场南楼2510室
    Copyright 2009-2017 上海净信实业发展有限公司 版权所有